Specification and Performance for the 2900 Water System
| Valve MaterialInlet/OutletCycles | Lead Free Brass2"" NPT (female)5 |
| Flow Rate (50 psi inlet) Continuous (15 psi drop) Peak (25 psi drop)CvMaximum Backwash (25 psi drop) | Valve Alone System106 gpm 84 gpm140 gpm 105 gpm27.525 gpm 22 gpm |
| Regeneration:Downflow/UpflowAdjustableTime Available | YesYes164 minutes |
| Meter Accuracy Range Meter Capacity Range 1" | 3-150 gpm +/- 5%Standard: 1,250-21,250 galsExtended: 6,250-106,250 gals. |
| Dimensions: Distributor Pilot Drain Line Brine Line Mounting Base Height (from top of tank) | 1-1.5" Pipe I.D.3/4" NPT (male)3/8" or 1/2" compression4"-8 UN12" |
| Tank Application - can regenerate/backwash the following: Water Softener Iron Filter Sediment Filter Carbon Filter Neutralizing Filter | 14"-30" diameter14"-21" diameter14"-21" diameter14"-21" diameter14"-21" diameter |
| Electrical RatingPressureTemperature | 24v, 110v, 220v-50Hz, 60HzHydrostatic: 300 psiWorking: 25-125 psi34-110 F |
| Cycles:1. Backwash (Upflow)2. Brine & Slow Rinse (Downflow)3. Rapid Rinse (Downflow)4. Brine Tank Refill5. Service (Downflow) | Typical Time:10 minutes60 minutes10 minutes12 minutes |
| Options:Backwash filterHot waterMeter initiated regenerationManual operationService valve operator | No hard water bypass pistonElectronic timerEnvironmental coverNickel Plating |